Probe Repair

We Repair All Major Ultrasound Brands

Including but not limited to the brands below. For brands not listed, contact us to check repairability.

GE
Philips
Siemens
Mindray
SonoScape
Samsung
Canon
Esaote

MYPRO is an independent service provider with no affiliation, endorsement or authorized partnership with any OEM listed above.

Probe Types

Common Probe Types

Convex / abdominal probe repair

Abdominal / Convex Probes

Common probes for abdominal, obstetric and gynecological scanning.

Linear probe repair

Superficial / Linear Probes

Musculoskeletal, superficial vascular and small-organ examinations.

Phased array / cardiac probe repair

Cardiac / Phased Array Probes

Echocardiography and cardiac examinations.

4D / volumetric probe repair

4D / Volumetric Probes

Repair and testing of real-time 3D imaging probes.

Endocavitary probe repair

Endocavitary Probes

Probes for gynecological endocavitary examinations.

Specialty probe repair

Anorectal / Rectal Probes

Probes for prostate and rectal wall examinations.

Fault Types

Common Failure Types

Physical & Structural Damage

Cracked or bulging lens, cracked housing, broken strain relief, damaged cable jacket, broken cable.

Image Abnormalities

Dark zones, flicker, interference stripes, partial dropouts, non-uniform image.

Performance Degradation

Element dropout, reduced sensitivity, poor penetration.

Functional Failures

Probe alarms, system fails to recognize the probe, 4D not working.

Quick reference

Common Fault Quick Reference

SymptomLikely causeRepair approach
Dark areas, streaks or local loss of imageFailed, degraded or open array elementsElement-level testing to locate the fault; crystal-array repair
Lens cracks, bulging or delaminationLong-term couplant attack or impact damageLens replacement or re-potting repair
Cable jacket damaged or brokenRepeated bending, wear and pullingFull cable replacement or local repair
Probe alarm; system does not recognize itWorn connector or internal circuit faultConnector replacement; circuit repair
Overall dim image, poor penetrationAged acoustic head or degraded lens acousticsAcoustic head replacement; acoustic performance restoration
4D volume probe not working, vibration or noiseDrive motor, dome or oil bladder fault4D motor service; dome and oil bladder replacement
Repair Check

Check Repair Options

Tell us what you would like to know:

(1) To confirm whether this probe can be repaired first — send us the brand and model (brands beyond those listed above are welcome);
(2) To get a repair plan and quote directly — please describe the failure symptoms.

How It Works

Service Process · Seven Transparent Steps

From first contact to delivery you receive progress updates at every stage: diagnose first, then quote — repair starts only after you approve the price and turnaround.

01

Initial Contact

Describe the probe failure and system model by phone, WeChat or form.

02

Probe Intake

Ship by courier — safe and convenient.

03

Testing & Diagnosis

Full electronic testing and evaluation to pinpoint the fault and define the repair plan.

04

Customer Approval

A clear quote and turnaround — repair starts only after your approval. No pressure, no surprises.

05

Cleanroom Repair

Repaired in our own Class 100,000 cleanroom with self-supplied core parts and controlled, documented processes.

06

Warranted Delivery

Shipped back after passing testing, with a written warranty — the same issue is fixed free of charge.

07

After-Sales Follow-Up

Verifiable service records, free re-inspection within the warranty, data-driven continuous improvement.

SLA Turnaround Standard repair5–10 business days Special specifications or requirementstimeline confirmed after evaluation

Our Commitment

Our Repair Commitments

Diagnose First, Then Quote

A written quote and turnaround are issued after testing; repair starts only after your approval.

No Fix, No Fee

If testing confirms a probe cannot be repaired, only the pre-disclosed diagnosis fee applies — no repair charges.

Quality Confirmation

Performance testing and on-system verification before delivery — a probe is "fixed" only when imaging meets the standard.

Warranty Coverage

The same failure recurring at the repaired area within the warranty period is reworked free of charge.

Fully Traceable

Every probe gets an end-to-end service record and a unit-level test report, verifiable at any time.

Fair Dispute Resolution

Disagreements are resolved through consultation in the spirit of long-term partnership — our partners never bear an unfair loss.

Book a Repair

Book a Repair

Diagnose first, then quote — repair starts only after you approve the price and turnaround.

Book Now

Line height 1.70
Line width 296px
Edit mode
Click any text to edit it
Click an image to replace it
Auto-saves 1 s after you stop
Survives closing the page, but not switching computers
When done, click 💾 Save to file to write back to this page