Manufacturing & Quality Control

Manufacturing & Quality Control

A probe is a precision acoustic device — you can only repair as well as you can manufacture. With our own Class 100,000 cleanroom line, all eight core processes are completed in-house,

with every probe and every element tested and compared against OEM baselines. Manufacturing capability and quality data together define MYPRO’s delivery bottom line.

Class 100,000

cleanroom

8

core processes in-house

±2dB

per-element acceptance limit

One file per unit

data traceable end to end

Dual ISO

9001 · 13485 in progress

30+ yrs

team industry experience

Products

From Baseline to Documentation: the Data Chain Behind Every Product

Baseline → Design → Manufacturing → In-process inspection → Verification → Documentation. Six steps, and every unit leaves a verifiable data trail.

Establish Baseline

Measured acoustic and geometric parameters of OEM units serve as the manufacturing baseline — everything starts from data.

Design

In-house acoustic structure design — every parameter of the array, matching layers and backing is computable and traceable.

Manufacturing

Core processes run on our own production line, with process parameters recorded on the work order — no “black-box manufacturing”.

In-Process Inspection

Self-inspection after each process, plus patrols on key steps; parameters recorded on the work order — failures never move to the next step.

Verification

Element-by-element testing with a ±2dB acceptance limit; on-system comparison confirms equivalence; test reports in both dB and cm ship with the probe.

Documentation

Measurement methods are codified into company acceptance standards; one file per unit, with key process parameters and test results traceable end to end.

Process & Quality

Core Manufacturing Processes & Inspection

Production line in practice: the first four are core process steps, the last four are inspection steps recorded unit by unit — process parameters and test data go into the same per-unit file.

01 Wafer dicing — piezoelectric wafers are precisely diced into array elements, laying the foundation of the acoustic field.
02 Lens potting — the acoustic lens is potted in one piece to secure sound transmission and focusing.
03 Acoustic stack bonding — matching layer, piezoelectric elements and backing are bonded layer by layer to form the core of the acoustic head.
04 Encapsulation & curing — full encapsulation and curing ensure long-term stability and sealing.
05 Element-by-element scanning — sensitivity and consistency are checked element by element to locate any hidden defect.
06 Acoustic measurement — key acoustic parameters are measured one by one against the design baseline.
07 Phantom testing — imaging performance is verified on a standard phantom, close to real clinical use.
08 Clinical validation — on-system imaging is validated and all data archived for traceability.

Wafer dicing
01 ProcessWafer Dicing
Lens injection
02 ProcessLens Molding
Acoustic head stacking
03 ProcessAcoustic Head Stacking
Encapsulation and curing
04 ProcessEncapsulation & Curing
Element consistency measurement: software interface and sensitivity curve
05 InspectionElement Scanning
Acoustic measurement
06 InspectionAcoustic Measurement
Phantom test: probe placed in an ATS phantom for acoustic performance measurement
07 InspectionPhantom Test
Clinical verification: system installation site and clinical application
08 InspectionClinical Verification

All photos are taken on our production line. Visits are welcome by appointment — inspect the equipment and work in progress in person.

Design Verification

Design Verification: In-House Components vs OEM Baseline

Same probe, same station, same conditions — measured data comparison.

C1-6 AUTO on: MP acoustic head

AUTO On · MP acoustic head · GE C1-6

C1-6 AUTO on: OEM acoustic head

AUTO On · OEM acoustic head · GE C1-6

C1-6 AUTO off: same gain, MP left and OEM right

AUTO Off · Same Gain · MP left / GE OEM right · C1-6

C1-6 AUTO off: OEM minus 5dB, MP left and OEM right

AUTO Off · OEM −5dB · MP left / GE OEM right · C1-6

S5-1 target comparison, MP left and OEM right

Target Comparison · PHILIPS S5-1

S5-1 brightness comparison, MP left and OEM right

Brightness Comparison · PHILIPS S5-1

S5-1 artifact comparison, MP left and OEM right

Artifact Comparison · PHILIPS S5-1

Two measured comparison sets (same system, same conditions): top row GE C1-6 — AUTO on shows MP and OEM acoustic heads separately, AUTO off shows MP on the left and OEM on the right; bottom row PHILIPS S5-1 — target, brightness and artifact comparisons, all with MP on the left and OEM on the right.

Final Inspection

Final Inspection

Covers the items below; per-element acoustic echo test results are compared directly against the baseline, controlling quality consistency with data.

01 Visual inspection

02 Per-element acoustic echo test

03 Electrical safety test

04 On-system imaging verification

05 Air-image paperclip test

06 Cable inspection

07 Traceability record

08 Release sign-off

Every repaired probe ships with a unit-level test report, including:
Probe identity (model · serial number · connector type)→ Reported fault (customer report + photos)→ Pre-repair diagnosis (element map · electrical data · optical photos)→ Repair work performed (detailed process records)→ Post-repair test data (element map · electrical safety · seal integrity · on-system imaging)→ Release approval (testing engineer signature · date)

Contact Mr. Wu for a complete sample test report, or receive one with your probe evaluation.

Detailed test data available on request.

Compliance

Compliance

Electrical Safety

Insulation resistance and leakage current tested unit by unit per IEC 60601-1 / IEC 62353 — safety is the compliance bottom line and is checked before every delivery.

Biocompatibility

Patient-contact materials all carry biocompatibility test reports (ISO 10993 series) and withstand standard disinfection protocols; report numbers are filed in the per-unit record, traceable with each delivery.

Element Consistency

A ±2dB acceptance limit, in line with OEM internal controls and published industry standards; statistics cover both standard deviation and maximum deviation to expose outlier dead elements.

The Boundary of Repair & Remanufacturing

Per regulators: replacement parts that are engineering-verified as equivalent to OEM parts in form, fit and function fall within restorative repair; equivalence measurement and mandatory verification each cover different ground — verification answers “can it be used legally”, equivalence measurement answers “how close is it”.

Credentials & Systems

National

High-Tech Enterprise

Dual ISO

certification in progress

Class 100,000

cleanroom

30+ yrs

team industry experience

Sci-Tech SME

registered

Tax credit A

consecutive years

Plant Visit

Visit the Line or Discuss Partnership

See the equipment, the processes and the test data — book a day ahead at a time that suits you.

Book Now

Line height 1.50
Line width 222px
Edit mode
Click any text to edit it
Click an image to replace it
Auto-saves 1s after you stop
Saved in this browser (not across computers)
When done, click 💾 Save to file to write back